Millennium 2000 Rack Mountable 19" PDU-42 Circuit ( 17U)
Infinity Series-Three Phase, 240/120 or 208/120VAC.
28.7 KVA at 208VAC;33.2 KVA at 240VAC
Overview
The RPDU is available in a 17U or 10U high configuration. It is designed with a complete single or three phase circuit breaker panel, advanced metering, and a variety of plug and play output receptacles that can deliver up to 33 KVA
Real estate: The RPDU will free valuable computer room space, which is usually occupied by bulky distribution equipment and NEC required clearances around panels.
Installation cost: Power distribution is costly, and circuit wiring could cost several thousand of dollars. The RPDU addresses this issue by delivering 33KVA of plug and play receptacles powering up to 16 racks with only one input circuit.
Installation time: Conventional wiring could take several days to complete, while the RPDU power distribution can be available within a few hours due to the simplicity of the installation.
Quality: Field installed circuits are usually not load tested, therefore reducing the reliability and quality of the distribution circuits and increasing the chance of future failures. The RPDU distribution unit is load tested and each individual receptacle is loaded to 100% of its capacity.
Flexibility: Addition of future circuits in a computer room requires downtime and additional cost. By using the RPDU, load addition is easy, just plug the new equipment in to an available receptacle.
Relocation and reconfiguration: The RDPU can be easily relocated at no additional cost to the end user. Where as in conventional wiring, a total abandonment of the distribution circuits is expected.
Air conditioning: Conduits under computer room floors restrict AC airflow, thus resulting in added cost for additional AC units. By utilizing the RPDU distribution, under floor congestion will be resolved.
Fire Suppression : By using the RPDU distribution, all receptacles are above the computer room floor, which will eliminate the need for fire suppression system required by the city fire codes
Branch Circuit Monitor Option:
The RPDU can be equipped with a Branch Circuit Monitor.
The RPDU monitors the current draw of each individual circuit. Each circuit can be programmed to provide a warning and a critical alarm.
All data is transmitted to a computer or network (Modbus host) for management and monitoring. Up to 63 RPDUs can be networked on one Modbus for simple wiring
Load Monitoring: The RPDU is equipped with an advanced power meter. The meter transmits all data to a Palm Pilot Organizer via an infrared port, then to an Excel spreadsheet for record keeping and management.
Universal operation: The RPDU operates as a single or three phase distribution, and interfaces with a variety of AC power supply systems.
Remote Equipment connection: The RPDU has knockouts on the top and bottom panels, and spare circuits to distribute power to any location in the computer room.
Available in two load receptacle configurations:
Panel A includes: Two L6-30R, two L6-20R, eight 5-20R, two L5-30R, and two L5-20R receptacles.
Panel B includes: Two L6-30R and 14 L5-20R receptacles
* Mountable on standard 19-in. racks
* Serves as a main PDU or sub-PDU
* Available in a single- or 3-phase configuration or with one- or dual-input capability
* Equipped with metering system to monitor the power and rack load
* Supports external circuit runs for stand-alone equipment
Specifications
Three phase 42 circuit panel, 240/120 or 208/120 VAC.
Main circuit breaker 3 pole 100 amps
16 dedicated load breakers for each receptacle on the back panel.
Power Monitor: Per phase KW, PF, Current, Volts L-L & L-N,
Total KVA, KW, KVAR, PF, KW max, and KWH,
Meter Software: Software for palm pilot interface, downloads all readings to a palm pilot then to a computer excel spreadsheet
Panel A receptacles:2 ea. L6-30, 2 ea. L6-20, 2 ea. L5-30, 2 ea. L5-20, and 8 ea. 5-20.
Optional Panel B receptacles:2 ea. L6-30, and 14 ea. L5-20.
Optional Panel C receptacles:16 ea. L6-20 or 30
Optional Panel D receptacles:11 ea. L21-20 or 30
Over 15 spare circuits for external use with conduit (Conventional wiring).
Knock-outs on the top and bottom for conduit connections.
Dimensions: 30"H x 17.5"W x 15.5"D
Paint: Black
Availabel Options: Branch Circuit Monitor and other items call for pricing
Additional Info
All pricing subject to change. For all prices, products and offers, Mainline Computer Products 460 Village Park Powell Ohio reserves the right to make adjustments due to changing market conditions, product discontinuation, manufacturer price changes, errors in advertisements and other extenuating circumstances.
High volume bids are welcome. Call (800)-686-5312, Ext. #228 or e-mail: Sales@mldelivers.com
While Mainline Computer Products Inc. makes reasonable efforts to include accurate and up-to-date information on the site, Mainline makes no warranties or representations as to the site's accuracy. Mainline assumes no liability or responsibility for any errors or omissions in the content on the Site.
|