Mainline Computer HotLok Blanking Panel w/ Temperature Strip


Products

Showing 1 - 2 of 2« Previous | Page: 1 | Next »

HotLok™ 1U Blanking Panels 9.5mm Square w Upsite Temperature Strip #10025
HotLok™ 1U Blanking Panels 9.5mm Square w Upsite Temperature Strip #10025
Sealing Solution that Eliminates Air Recirculation Problems in the Server Cabinet- Carton (10 Each)
Contact Us
HotLok™ 1U Blanking Panels M5 / 10-32 Round w Upsite Temperature Strip #10035
HotLok™ 1U Blanking Panels M5 / 10-32 Round w Upsite Temperature Strip #10035
Sealing Solution that Eliminates Air Recirculation Problems in the Server Cabinet- Carton (10 Each)
HotLok™ 1U Blanking Panels M5 / 10-32 Round w Upsite Temperature Strip #10035
Contact Us
Showing 1 - 2 of 2« Previous | Page: 1 | Next »
Applications:

The HotLok® Temperature Strip is a liquid crystal thermometer with an acrylic self-adhesive backing that quickly and accurately measures the intake air temperature of IT equipment. It indicates whether the air temperature is within acceptable limits based on the standards established by the American Society of Heating, refrigerating, and Air Conditioning Engineers (ASHRAE) and equipment manufacturers. Measurement of equipment intake air temperature is used in the management of all elements of cooling infrastructure such as the number and type of perforated tiles or grates, cooling unit temp set points, and cooling unit airfl¬ow volumes.

Features:

Measurement Ranges

The HotLok® Temperature Strip has both Celsius and Fahrenheit temperature scales.
• Celsius Scale: 10° C to 39° C in increments of 1° C
• Fahrenheit Scale: 50° F to 102° F in increments of 2° F

Temperature Ranges
• Blue: Recommended Operating Range based on recommendations from ASHRAE for Class A1 to A4 rooms
• (Temperature Range: 18° to 27° C, or 64° to 80.6° F)

• Yellow: Allowable Operating Range based on recommendations from ASHRAE for Class A1 rooms
• (Temperature Range: 15° C or 32° C or 59° F or 90° F)

• Red: Outside Allowable Operating Range for Class A1 rooms; indicates conditions above 32° C or 90° F or
• below 15° C or 59° F, either of which may result in increased equipment failure rates.