APC # RACSC112E -InRow SC System 6.5kW
• 1 InRow SC, 1 NetShelter SX Rack 600mm, and Rear Containment
Overview
The APC InRow SC RACSC112 System is 1 InRow SC, 1 NetShelter SX Rack 600mm, with Front and Rear Containment which is a rapidly deployable, self-contained row-based cooling solutions for server rooms and wiring closets.
APC RACSC112 Features:
Active response controls- Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Includes:
• (1) NetShelter SX 42U 600mm Wide x 1070mm Deep Enclosure
• (1) InRow SC 200-240V 60HZ
• (2) APC Rack Air Containment End Caps
• (1) APC Rack Air Containment Front Assembly for InRow 300mm
• (1) APC Rack Air Containment Front Assembly for NetShelter SX 42U 600mm Wide
• (1) APC Rack Air Containment Rear Assembly for InRow 300 mm
• (1) APC Rack Air Containment Rear Assembly for NetShelter SX 42U and InRow 600mm
• Installation guide
Standard Lead Time: Special Order - Call for Quoted Lead Times
InRow SC Features & Benefits:
• Self-contained design- The unit is quickly and easily installed without refrigerant lines or remote heat exchangers. The unit requires only power, condensate drain and an available return plenum to provide effective cooling.
• Containment system compatible- The unit can be combined with a rack-level containment system to eliminate hot air mixing and maximize cooling efficiency.
• In-Row architecture- Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
• Modular design- Modular design provides scalable solutions to add cooling as demand increases.
• Real-Time Capacity Monitoring- Real-time display of current and available cooling.
• Microprocessor controller- Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
• Network manageable- View the user interface with a browser. Provides quick access from anywhere on a secure network.
• Building Management System Integration- Send alarms and data points allowing you to manage critical building infrastructure from a single system.
• Ducted condenser air- Uses unconditioned air from plenum space to reject the heat rather than conditioned room air.
• Built-In Condensate Pump- Factory installed pump collects and removes water from the air conditioner, ensuring continuous operation.
• High Head Pressure Protection- Ensures the InRow SC remains operational even when the condenser inlet air is restricted or very hot.
• Coil freeze protection- Hot gas bypass prevents evaporator coil from freezing during light load conditions.
• Predictive failure notification- Maximizes system availability by providing early warning of required fan or filter replacement.
• Automatic restart- Returns the unit to its last operating status in the event of a power failure.\
• Hot swappable fans- Allows system to remain operational if a fan replacement is required.
• Washable filters- Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
• Easy service access- In-row equipment allows for all serviceable components to be replaced/maintained in the hot or cold aisle.
• Rack Inlet Temperature Control- Reduces the risk of hot spots at the rack level
• Variable speed fans- Variable speed fans reduce energy consumption during off-peak cooling periods.
• Green Refrigerant- Environmentally friendly refrigerant that can offer LEED points.
Specifications
APC RACSC112 Specifications:
Mechanical
Height: 78.40 in. (1991 mm.)
Width: 35.43 in. (900 mm.)
Depth: 58.13 in. (1477 mm.)
Weight: 823.30 lbs. (374.23 kg.)
Color: Black
Environmental
Audible noise at 1 meter from surface of unit: 70.00 dBA
General
Cooling Options: Air-cooled Self-contained
Compressor Type: Rotary
Air Discharge Patterns: Horizontal
Intake Air: Rear Return
Refrigerant: R410A
Refrigerant Charge: 3 pounds
Air Flow: 1200 CFM
Condensate Pump Capacity: 1.30 gal/hour:
Amp Draw Nominal: 16A
Amp Draw In-Rush: 56
Input Power: 2940 Watts
Input Frequency: 60 Hz
Rack Height: 42U
Input Connections: NEMA L6-20P
Communications & Management
Control panel: Multi-function LCD status and control console
Additional Info
All pricing subject to change. For all prices, products and offers, Mainline Computer Products 460 Village Park Powell Ohio reserves the right to make adjustments due to changing market conditions, product discontinuation, manufacturer price changes, errors in advertisements and other extenuating circumstances.
High volume bids are welcome. Call (800)-686-5312, Ext. #228 or e-mail: Sales@mldelivers.com
While Mainline Computer Products Inc. makes reasonable efforts to include accurate and up-to-date information on the site, Mainline makes no warranties or representations as to the site's accuracy. Mainline assumes no liability or responsibility for any errors or omissions in the content on the Site.
|