HotLok® Blanking Panels for Server Rack Airflow Management

Improve server-rack airflow and cooling effectiveness with HotLok® Blanking Panels from Upsite Technologies. These purpose-built rack filler panels seal unused equipment openings, helping prevent hot exhaust air from recirculating to the front of the cabinet and reducing the loss of conditioned air through open rack spaces.

HotLok Blanking Panels are designed for fast, tool-free installation in standard EIA-310-E equipment openings. Their cantilevered sealing vanes close gaps between adjoining panels and installed equipment, providing a seal that the manufacturer reports is 29% better than the nearest competitive panel.

By separating conditioned supply air from equipment exhaust air, HotLok panels help reduce bypass airflow and rack hot spots. They can also support more consistent equipment inlet temperatures and allow data center operators to make better use of existing cooling capacity.

HotLok Blanking Panel Features

  • Tool-free, snap-in installation with no additional hardware required
  • Available in 1U and 2U configurations
  • Compatible with standard EIA-310-E rack openings
  • Cantilevered sealing vanes help close gaps between panels and equipment
  • Ergonomic finger grips provide convenient installation and removal
  • Interlocking construction allows panels to be stacked for organized storage
  • Available in traditional black and reflective white
  • Suitable for new or existing server racks and network cabinets
  • UL 94 HB fire rating
  • RoHS compliant

Operational Benefits

  • Reduces bypass airflow through unused rack openings
  • Helps prevent hot exhaust air from recirculating to equipment intakes
  • Reduces the potential for hot spots within server cabinets
  • Helps deliver conditioned air to the upper portion of the rack
  • Supports hot-aisle and cold-aisle airflow-management strategies
  • Improves utilization of existing cooling-system capacity
  • Supports consistent rack configuration and airflow-management standards
  • Installs and relocates quickly as rack equipment configurations change
  • May support energy savings by enabling cooling-system set-point adjustments after airflow conditions are properly evaluated